Prince PVC Pipes and Fittings  By  SARHAD PLASTIC
 

Home About Us Products Contact Us Guidelines
 
  PRODUCT RANGE
u.PVC Pipes
u.PVC Fittings
Tube well Casing and Screen Pipes
Water Supply and Distribution
Sewerage System
Electrical Pipes

 
 



 

PRODUCTS

PRINCE RIGID u.PVC PRESSURE PIPES

PRINCE unplasticized Poly Vinyl Chloride pipes are produced according to the specifications under the technical know-how of British Standards, Pakistan Standards and other International Standards.

Four types of pressure pipes are produced at present, B-Class for working pressures up to 6 kg/cm2, C-Class for working pressure up to 9 kg/ cm2, D-Class for working pressure up to 1 kg / cm2 and E-Class for working pressure up to 15 kg / cm2. All Ranges of PRINCE fittings and accessories for these pipes are also available. For any other special requirements we can also produce Special -  Class Pipes.

ADVANTAGES

PRINCE PVC PIPES provide the following distinct advantages:

EASY INSTALLATION
Requiring no special tools or skilled personnel. PVC pipes are easier to install a other piping systems.

LIGHT WEIGHT
PVC pipes are lighter in weight than traditional cast iron pipes. This gives saving i handling and installation costs.

STRENGTH
PVC pipes are regarded as being flexible when properly installed in a trench usinG suitable bedding and backfill. PVC pipes, have better impact strength than its iron a clay counter part.

NON-TOXIC
Do not change the taste or smell of water.

CORROSION RESISTANCE
PVC pipes do not undergo physical deterioration due to corrosive sub soil.

NON - FLAMMABLE
PVC pipes do not support combustion.

WEIGHT OF u.PVC PIPE PER METER (Minimum)

British Standard 3505 does not indicates weight of pipes, it depends on the formation, density and tolerance. Approximate weight for Prince uPVC pipes are given in the table below.

 

Nominal Size

CLASS-B

CLASS-C

CLASS-D

CLASS-E

 

Kgs/M

Kgs/M

Kgs/M

Kgs/M

3/8"

-

-

-

0.11

1/2"

-

-

-

0.15

3/4"

-

-

-

0.22

1"

-

-

-

0.32·

1 1/4"

-

-

0.41

0.50

1 1/2"

-

-

0.54

0.65

2"

-

0.68

0.82

1.03

2 1/2"

-

1.01

1.20

1.58

3"

1.17

1.41

1.82

2.22

4"

1.78

2.32

3.03

3.65

5"

2.44

3.49

4.55

5.51

6"

3.46

5.01

6.57

7.95

8"

5.30

7.72

10.05

12.17

10"

8.26

11.95

5.59

18.89

12"

11.55

16.85

21.51

26.28

14"

13.87

20.27

26.49

36.16

16"

18.17

23.14

-

-

18"

23.14

33.83

-

-

 

MAXIMUM SUSTAINED WORKING & TEST PRESSURES

 

WORKING PRESSURE

TEST PRESSURE

Class

bar

Kgf/cm2

Ibf/in2

B

6

6.12

87

C

9

9.18

130

0

12

12.25

173

E

15

15.30

217

bar

Kgf/cm2

Ibf/in2

9

9.18

130

14

13.77

195

18

18.38

259

23

22.95

325

The maximum admissible service pressures are calculated from known data on the basis of a life atleast 50 years of continuous operation and
a safety factor greater than 2

 

SHORT-TERM HYDROSTATIC PRESSURE RESISTANCE AT 20°C.
MAXIMUM 1 H FAILURE PRESSURE.

bar

Ibf/in2

6 bar class - B  

21.6 bar

9 bar class - C

32.4 bar

12 bar class - D

43.2 bar

15 bar class - E

54.0 bar

 

PRINCE u.PVC PIPE
DIMENSIONS OF CLASS B, C, D & E according to

BS - 3505 & PS - 3051

 

 

 

 

 

WALL THICKNESS

 

 

 

 

 

B-Class

C-Class

D-Class

E-Clas5

 

 

 

6.0 bar

9.0 bar

12.0 bar

15.0 bar

Nominal Outside

(60m head

(90m head

120m hea

(150m head

Size

Diamete

of water)

of water)

of water)

of water)

 

Min.

Max.

Min.

Max.

Min.

Max.

Min.

Max.

Min.

Max.

Inch

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

3/8"

17.0

17.3

 

 

 

 

 

 

1.5

1.9

1/2"

21.2

21.5

 

 

 

 

 

 

1.7

2.1

3/4"

26.6

26.9

 

 

 

 

 

 

1.9

2.5

1"

33.4

33.7

 

 

 

 

 

 

2.2

2.7

11/4"

42.1

42.4

 

 

 

 

2.2

2.4

2.7

3.2

11/2"

48.1

48.4

 

 

 

 

2.5

2.8

3.1

3.4

2"

60.2

60.5

 

 

2.5

2.8

3.1

3.4

3.9

4.3

21/2"

75.2

75.5

 

 

3.0

3.3

3.9

4.5

4.8

5.3

3"

88.7

89.1

2.9

3.3

3.5

4.1

4.6

5.3

5.7

6.6

4"

114.1

114.5

3.4

4.0

4.5

5.2

6.0

6.9

7.3

8.4

5"

140.0

140.4

3.8

4.4

5.5

6.4

7.3

8.4

9.0

10.4

6"

168.0

168.5

4.5

5.2

6.6

7.6

8.8

10.2

10.8

12.5

8"

218.8

219.4

5.3

6.1

7.8

9.0

10.3

11.9

12.6

14.3

10"

272.6

273.4

6.6

7.6

9.7

11.2

12.8

14.8

15.7

18.1

12"

323.4

324.3

7.8

9.0

11.5

13.3

15.2

17.5

18.7

21.6

14"

355.0

356.0

8.5

9.8

12.6

14.5

16.7

19.2

20.5

23.6

16"

405.9

406.9

9.7

11.2

14.5

16.7

19.0

21.9

23.4

27.0  

18"

456.7

457.7

11.0

12.7

16.3

18.8

21.4

24.6

0.0

0.0

20"

507.5

508.5

12.2

14.1

18.1

20.9

0,0

0.0

0.0

0.0

22"

558.3

559.3

13.4

15.5

19.9

22.9

0.0

0.0

0.0

0.0

 

PRINCE u.PVC PIPE
DIMENSIONS OF according to

ASTM 0-1785 SCHEDULE - 40

 

Outside Dia

Wall Thickness

Nominal

 

Nominal Size

(d)

 

 

 

 

Pressure

Inches

 

(S)

 

Avg. Weight

Rating

 

mm

 

mm

 

Kg/m

 

 

 

Min

 

Max

 

Bar

1/2"

21.34

2.77

 

3.28

0.24

41.41

3/4"

26.67

2.87

 

3.38

0.33

33.10

1"

33.40

3.38

 

3.89

0.48

31.10

11/4"

42.16

3.50

 

4.06

0.65

25.50

11/2"

48.26

3.68

 

4.19

0.77

22.80

2"

60.32

3.91

 

4.42

1.04

19.30

21/2"

73.12

5.15

 

5.77

1.62

20.50

3"

88.90

5.49

 

6.15

2.14

17.90

4"

114.30

6.02

 

6.73

3.05

15.20

6"

168.28

7.11

 

7.98

5.37

12.40

8"

219.08

8.18

 

9.20

8.11

11.00

Pressure ratings apply only unthreaded pipes at 23° C. Threading of Sch-40 pipes is not recommended. The Standard (L) is 6 meters.

 

PRINCE u.PVC PIPE
DIMENSIONS OF according to

ASTM D-2241 SDR-SERIES

Nominal

Outside Dia

Wall Thickness

Nominal

Pressure

Size

(d)

(5)

Avg. Weight

Rating

Inches

mm

mm

Kg/m

Bar

2" SDR-26

60.32

2.8

0.768

11.00

3" SDR-32.5

88.90

2.7

1.093

8.62

3" SDR-26

88.90

3.5

1.417

11.00

4" SDR-41

114.30

3.2

1.667

6.89

4" SDR-32.5

114.30

4.0

2.082

8.62

4" SDR-26

114.30

4.5

2.333

11.00

6" SDR-64

168.28

3.2

2.450

4.34

6" SDR-41

168.28

4.5

3.445

6.89

6" SDR-32.5

168.28

5.2

3.987

8.62

8" SDR-41

219.08

6.0

5.988

6.89

8" SDR-32.5

219.08

7.0

6.987

8.62

The Standard Length (L) is 6 meters.

 

PRINCE u.PVC PIPE
DIMENSIONS OF according to

DIN - 8062

 

 

Wall Thickness

 

Nominal Size

Series 2

Series 3

Series 4

Series 5

 

4 bar

6 bar

10 bar

16 bar

mm

 

 

 

 

mm

mm

mm

mm

20

-

-

-

1.5

25

-

-

1.5

1.9

32

-

-

1.8

2.4

40

-

1.8

1.9

3.0

50

-

1.8

2.4

3.7

63

-

1.9

3.0

4.7

75

1.8

2.2

3.6

5.6

90

1.8

2.7

4.3

6.7

110

2.2

3.2

5.3

R?

125

2.5

3.7

6.0

q1

140

2.8

4.1

6.7

tn 4

160

3.2

4.7

7.7

11 q

200

4.0

5.9

9.6

14 q

225

4.5

6.6

10.8

1 f) 7

250

4.9

7.3

11.9

1A h

280

5.5

8.2

13.4

?n A

315

6.2

9.2

15.0

?1 A

355

7.0

10.4

16.9

?h 1

400

7.9

11.7

19.1

?q 7

450

8.9

13.2

21.5

-

500

9.8

14.6

23.9

-

560

11.0

16.4

26.7

-

630

12.4

18.4

30.0

-

For irrigation, drainage and cable ducting working pressures are given at a temperature of 20° C.

 
HomeAbout UsProductsContact UsGuidelines 